Solve collaborative project inconsistencies before execution
On executing a collaborative project, the Execution Sanity Check wizard may display the following issues.
For more information about collaborative projects, see Design collaborative projects.
Message
Missing Virtual User X in Population Y
Description
In the collaborative project, Population Y is configured to use a Virtual User X that does not exist.
Resolution
Population Y must be modified, as described in Configure a population or the missing Virtual User X must be recreated, as described in Create a Virtual User.
Message
Missing Population X for Scenario Y
Description
In the collaborative project, scenario Y is configured to use X population that does not exist.
Resolution
Scenario Y must be modified or missing population X must be recreated, as described in Populations.
Message
Missing Population X in policy Y for scenario Z
Description
In the collaborative project, scenario Z uses Y population which is missing.
Or scenario Z uses Y population which requires a missing X population.
Resolution
Missing Y population must be recreated, as described in Populations.
Or the runtime parameters of Y population must be modified, as described in Population advanced parameters or the missing X population must be recreated, as described in Populations.
.
Message
Missing Load Generator X in Scenario Y
Description
The test cannot start because the scenario Y is configured to use a Load Generator X that does not exist.
Resolution
The scenario Y must be modified, as described in Test settings or the Load Generator X must be recreated, as described in Zones and Load Generator hosts.
.
Message
Duplicated Load Generator X
Description
The cannot start because it because, in this collaborative project, the same Load Generator X is declared and selected twice.
Resolution
The Load Generator duplicate must be renamed or removed, as described in Zones and Load Generator hosts.
Message
Missing server X in request Y
Description
In the collaborative project, Y request refers to X server that does not exist.
Resolution
X server must be recreated, as described in Servers or the Y request must be modified, as described in HTTP requests.
Message
Missing Server X in monitor Y
Description
In the collaborative project, Y monitor refers to X server that does not exist.
Resolution
X server must be recreated, as described in Servers or the Y monitor must be modified, as described in Configure a monitor.
.
Message
Missing Monitoring Agent X in Monitored Machine Y
Description
In the collaboratif project, the monitored machine Y refers to a Monitoring Agent X that does not exist.
Resolution
The Monitoring Agent must be recreated, as described in Create and configure a monitoring agent or the monitored machine must be modified, as described in Configure a monitored machine.