Solve collaborative project inconsistencies at design time
Sharing components of a project among different team testers may bring a number of inconsistencies when opening, publishing, updating, or reverting a collaborative project with the collaboration server. The Project Sanity Check wizard may raise the following issues about missing elements in a collaborative project.
For more information about collaborative projects, see Design collaborative projects.
Message
Missing Virtual User X in Population Y
Description
In the collaborative project, Population Y is configured to use a Virtual User X that does not exist.
Resolution
Population Y must be modified, as described in Configure a population or the missing Virtual User X must be recreated, as described in Create a Virtual User.
Message
Missing Population X for Scenario Y
Description
In the collaborative project, scenario Y is configured to use X population that does not exist.
Resolution
Scenario Y must be modified or missing population X must be recreated, as described in Populations.
Message
Missing Population X in policy Y for scenario Z
Description
In the collaborative project, scenario Z uses Y population which is missing.
Or scenario Z uses Y population which requires a missing X population.
Resolution
Missing Y population must be recreated, as described in Populations.
Or the runtime parameters of Y population must be modified, as described in Population advanced parameters or the missing X population must be recreated, as described in Populations.
Message
Missing server X in request Y
Description
In the collaborative project, Y request refers to X server that does not exist.
Resolution
X server must be recreated, as described in Servers or the Y request must be modified, as described in HTTP requests.
Message
Missing Server X in monitor Y
Description
In the collaborative project, Y monitor refers to X server that does not exist.
Resolution
X server must be recreated, as described in Servers or the Y monitor must be modified, as described in Configure a monitor.
Message
Duplicated Load Generator: X
Description
In the collaborative project, the same Load Generator X is declared twice.
Resolution
The Load Generator duplicate must be renamed or removed, as described in Zones and Load Generator hosts