Home

 

Configuration worksheet

 

Use the following worksheet to record the values you will use for this configuration. Where numbers appear in the Reference column they indicate that the value must match that in the appropriate worksheet elsewhere in this book. The examples that follow in this chapter refer back to the values in the ID column of this table. The entries in the Parameter Name column are explained in Explanation of terms.

Configuration worksheet for SNA on an i5/OS system
ID Parameter Name Reference Example Used User Value
Definition for local node
1 Local network ID   NETID  
2 Local control point name   AS400PU  
3 LU name   AS400LU  
4 LAN destination address   10005A5962EF  
5 Subsystem description   QCMN  
6 Line description   TOKENRINGL  
7 Resource name   LIN041  
8 Local Transaction Program name   MQSERIES  
Connection to a Windows system

The values in this section must match those used in Table 1, as indicated.

9 Network ID 2 NETID  
10 Control point name 3 WINNTCP  
11 LU name 5 WINNTLU  
12 Controller description   WINNTCP  
13 Device   WINNTLU  
14 Side information   NTCPIC  
15 Transaction Program 7 MQSERIES  
16 LAN adapter address 9 08005AA5FAB9  
17 Mode 17 #INTER  
Connection to an AIX system

The values in this section must match those used in Table 1, as indicated.

9 Network ID 1 NETID  
10 Control point name 2 AIXPU  
11 LU name 4 AIXLU  
12 Controller description   AIXPU  
13 Device   AIXLU  
14 Side information   AIXCPIC  
15 Transaction Program 6 MQSERIES  
16 LAN adapter address 8 123456789012  
17 Mode 14 #INTER  
Connection to an HP-UX system

The values in this section must match those used in Table 1, as indicated.

9 Network ID 4 NETID  
10 Control point name 2 HPUXPU  
11 LU name 5 HPUXLU  
12 Controller description   HPUXPU  
13 Device   HPUXLU  
14 Side information   HPUXCPIC  
15 Transaction Program 7 MQSERIES  
16 LAN adapter address 8 100090DC2C7C  
17 Mode 17 #INTER  
Connection to a Solaris system

The values in this section must match those used in Table 1, as indicated.

9 Network ID 2 NETID  
10 Control point name 3 SOLARPU  
11 LU name 7 SOLARLU  
12 Controller description   SOLARPU  
13 Device   SOLARLU  
14 Side information   SOLCPIC  
15 Transaction Program 8 MQSERIES  
16 LAN adapter address 5 08002071CC8A  
17 Mode 17 #INTER  
Connection to a Linux (x86 platform) system

The values in this section must match those used in Table 1, as indicated.

9 Network ID 4 NETID  
10 Control point name 2 LINUXPU  
11 LU name 5 LINUXLU  
12 Controller description   LINUXPU  
13 Device   LINUXLU  
14 Side information   LXCPIC  
15 Transaction Program 7 MQSERIES  
16 LAN adapter address 8 08005AC6DF33  
17 Mode 6 #INTER  
Connection to an z/OS system

The values in this section must match those used in Table 1, as indicated.

9 Network ID 2 NETID  
10 Control point name 3 MVSPU  
11 LU name 4 MVSLU  
12 Controller description   MVSPU  
13 Device   MVSLU  
14 Side information   MVSCPIC  
15 Transaction Program 7 MQSERIES  
16 LAN adapter address 8 400074511092  
17 Mode 6 #INTER  
Connection to a VSE/ESA™ system

The values in this section must match those used in your VSE/ESA system.

9 Network ID 1 NETID  
10 Control point name 2 VSEPU  
11 LU name 3 VSELU  
12 Controller description   VSEPU  
13 Device   VSELU  
14 Side information   VSECPIC  
15 Transaction Program 4 MQ01 MQ01
16 LAN adapter address 5 400074511092  
17 Mode   #INTER  

 

Parent topic:

Configuration parameters for an LU 6.2 connection


ic17080_


 

Home