Home

 

Configuration worksheet

 

Use this worksheet to record the values you use for your configuration. Where numbers appear in the Reference column they indicate that the value must match that in the appropriate worksheet elsewhere in this book. The examples that follow in this chapter refer to the values in the ID column. The entries in the Parameter Name column are explained in Explanation of terms.

Configuration worksheet for Communications Server for Linux
ID Parameter Name Reference Example User Value
Parameters for local node
1 Configuration file name   sna_node.cfg  
2 Control point name   LINUXPU  
3 Node ID to send   05D 30A55  
4 Network name   NETID  
5 Local APPC LU   LINUXLU  
6 APPC mode   #INTER  
7 Invokable TP   MQSERIES  
8 Local MAC address   08005AC6DF33  
9 Port name   MQPORT  
10 Command path   /opt/mqm/bin/amqcrs6a  
11 Local queue manager   LINUX  
Connection to a Windows system

The values in this section of the table must match those used in Table 1, as indicated.

12 Link station name   NTCONN  
13 Network name 2 NETID  
14 CP name 3 WINNTCP  
15 Remote LU 5 WINNTLU  
16 Application TP 7 MQSERIES  
17 Mode name 17 #INTER  
18 CPI-C symbolic destination name   NTCPIC  
19 Remote network address 9 08005AA5FAB9  
20 Node ID to receive 4 05D 30F65  
Connection to an AIX system

The values in this section of the table must match those used in Table 1, as indicated.

12 Link station name   AIXCONN  
13 Network name 1 NETID  
14 CP name 2 AIXPU  
15 Remote LU 4 AIXLU  
16 Application TP 6 MQSERIES  
17 Mode name 9 #INTER  
18 CPI-C symbolic destination name   AIXCPIC  
19 Remote network address 8 123456789012  
20 Node ID to receive 3 071 23456  
Connection to an HP-UX system

The values in this section of the table must match those used in Table 1, as indicated.

12 Link station name   HPUXCONN  
13 Network name 4 NETID  
14 CP name 2 HPUXPU  
15 Remote LU 5 HPUXLU  
16 Application TP 7 MQSERIES  
17 Mode name 6 #INTER  
18 CPI-C symbolic destination name   HPUXCPIC  
19 Remote network address 8 100090DC2C7C  
20 node ID to receive 3 05D 54321  
Connection to a Solaris system

The values in this section of the table must match those used in Table 1, as indicated.

12 Link station name   SOLCONN  
13 Network name 2 NETID  
14 CP name 3 SOLARPU  
15 Remote LU 7 SOLARLU  
16 Application TP 8 MQSERIES  
17 Mode name 17 #INTER  
18 CPI-C symbolic destination name   SOLCPIC  
19 Remote network address 5 08002071CC8A  
20 Node ID to receive 6 05D 310D6  
Connection to an i5/OS system

The values in this section of the table must match those used in Table 1, as indicated.

12 Link station name   AS4CONN  
13 Network name 1 NETID  
14 CP name 2 AS400PU  
15 Remote LU 3 AS400LU  
16 Application TP 8 MQSERIES  
17 Mode name 17 #INTER  
18 CPI-C symbolic destination name   AS4CPIC  
19 Remote network address 4 10005A5962EF  
Connection to a z/OS system

The values in this section of the table must match those used in Table 1, as indicated.

12 Link station name   MVSCONN  
13 Network name 2 NETID  
14 CP name 3 MVSPU  
15 Remote LU 4 MVSLU  
16 Application TP 7 MQSERIES  
17 Mode name 6 #INTER  
18 CPI-C symbolic destination name   MVSCPIC  
19 Remote network address 8 400074511092  
Connection to a VSE/ESA™ system

The values in this section of the table must match those used in your VSE/ESA system.

12 Link station name   VSECONN  
13 Network name 1 NETID  
14 CP name 2 VSEPU  
15 Remote LU 3 VSELU  
16 Application TP 4 MQ01  
17 Mode name   #INTER  
18 CPI-C symbolic destination name   VSECPIC  
19 Remote network address 5 400074511092  

 

Parent topic:

Configuration parameters for an LU 6.2 connection


ic14170_


 

Home