Home
Configuration worksheet
Use this worksheet to record the values you use for your configuration. Where numbers appear in the Reference column they indicate that the value must match that in the appropriate worksheet elsewhere in this book. The examples that follow in this chapter refer to the values in the ID column. The entries in the Parameter Name column are explained in Explanation of terms.
Configuration worksheet for Communications Server for Linux ID Parameter Name Reference Example User Value Parameters for local node 1 Configuration file name sna_node.cfg 2 Control point name LINUXPU 3 Node ID to send 05D 30A55 4 Network name NETID 5 Local APPC LU LINUXLU 6 APPC mode #INTER 7 Invokable TP MQSERIES 8 Local MAC address 08005AC6DF33 9 Port name MQPORT 10 Command path /opt/mqm/bin/amqcrs6a 11 Local queue manager LINUX Connection to a Windows system The values in this section of the table must match those used in Table 1, as indicated.
12 Link station name NTCONN 13 Network name 2 NETID 14 CP name 3 WINNTCP 15 Remote LU 5 WINNTLU 16 Application TP 7 MQSERIES 17 Mode name 17 #INTER 18 CPI-C symbolic destination name NTCPIC 19 Remote network address 9 08005AA5FAB9 20 Node ID to receive 4 05D 30F65 Connection to an AIX system The values in this section of the table must match those used in Table 1, as indicated.
12 Link station name AIXCONN 13 Network name 1 NETID 14 CP name 2 AIXPU 15 Remote LU 4 AIXLU 16 Application TP 6 MQSERIES 17 Mode name 9 #INTER 18 CPI-C symbolic destination name AIXCPIC 19 Remote network address 8 123456789012 20 Node ID to receive 3 071 23456 Connection to an HP-UX system The values in this section of the table must match those used in Table 1, as indicated.
12 Link station name HPUXCONN 13 Network name 4 NETID 14 CP name 2 HPUXPU 15 Remote LU 5 HPUXLU 16 Application TP 7 MQSERIES 17 Mode name 6 #INTER 18 CPI-C symbolic destination name HPUXCPIC 19 Remote network address 8 100090DC2C7C 20 node ID to receive 3 05D 54321 Connection to a Solaris system The values in this section of the table must match those used in Table 1, as indicated.
12 Link station name SOLCONN 13 Network name 2 NETID 14 CP name 3 SOLARPU 15 Remote LU 7 SOLARLU 16 Application TP 8 MQSERIES 17 Mode name 17 #INTER 18 CPI-C symbolic destination name SOLCPIC 19 Remote network address 5 08002071CC8A 20 Node ID to receive 6 05D 310D6 Connection to an i5/OS system The values in this section of the table must match those used in Table 1, as indicated.
12 Link station name AS4CONN 13 Network name 1 NETID 14 CP name 2 AS400PU 15 Remote LU 3 AS400LU 16 Application TP 8 MQSERIES 17 Mode name 17 #INTER 18 CPI-C symbolic destination name AS4CPIC 19 Remote network address 4 10005A5962EF Connection to a z/OS system The values in this section of the table must match those used in Table 1, as indicated.
12 Link station name MVSCONN 13 Network name 2 NETID 14 CP name 3 MVSPU 15 Remote LU 4 MVSLU 16 Application TP 7 MQSERIES 17 Mode name 6 #INTER 18 CPI-C symbolic destination name MVSCPIC 19 Remote network address 8 400074511092 Connection to a VSE/ESA™ system The values in this section of the table must match those used in your VSE/ESA system.
12 Link station name VSECONN 13 Network name 1 NETID 14 CP name 2 VSEPU 15 Remote LU 3 VSELU 16 Application TP 4 MQ01 17 Mode name #INTER 18 CPI-C symbolic destination name VSECPIC 19 Remote network address 5 400074511092
Parent topic:
Configuration parameters for an LU 6.2 connection
ic14170_
Home