Inquire Channel Listener on Multiplatforms
The Inquire Channel Listener (MQCMD_INQUIRE_LISTENER) command inquires about the attributes of existing IBM MQ listeners.
Required parameters
- ListenerName (MQCFST)
- Listener name (parameter identifier: MQCACH_LISTENER_NAME).
This parameter is the name of the listener with attributes that are required. Generic listener names are supported. A generic name is a character string followed by an asterisk (*), for example ABC*, and it selects all listeners having names that start with the selected character string. An asterisk on its own matches all possible names.
The listener name is always returned regardless of the attributes requested.
The maximum length of the string is MQ_LISTENER_NAME_LENGTH.
Optional parameters
- IntegerFilterCommand (MQCFIF)
- Integer filter command descriptor. The parameter identifier must be any integer type parameter
allowed in ListenerAttrs except MQIACF_ALL.
Use this parameter to restrict the output from the command by
specifying a filter condition. See MQCFIF - PCF integer filter parameter for information about using this
filter condition.
If you specify an integer filter, we cannot also specify a string filter using the StringFilterCommand parameter.
- ListenerAttrs (MQCFIL)
- Listener attributes (parameter identifier: MQIACF_LISTENER_ATTRS).
The attribute list might specify the following value on its own- default value if the parameter
is not specified:
- MQIACF_ALL
- All attributes.
or a combination of the following:
- MQCA_ALTERATION_DATE
- Date on which the definition was last altered.
- MQCA_ALTERATION_TIME
- Time at which the definition was last altered.
- MQCACH_IP_ADDRESS
- IP address for the listener.
- MQCACH_LISTENER_DESC
- Description of listener definition.
- MQCACH_LISTENER_NAME
- Name of listener definition.
- MQCACH_LOCAL_NAME
- NetBIOS local name that the listener uses. MQCACH_LOCAL_NAME is valid only on Windows.
- MQCACH_TP_NAME
- The LU 6.2 transaction program name. MQCACH_TP_NAME is valid only on Windows.
- MQIACH_ADAPTER
- Adapter number on which NetBIOS listens. MQIACH_ADAPTER is valid only on Windows.
- MQIACH_BACKLOG
- Number of concurrent connection requests that the listener supports.
- MQIACH_COMMAND_COUNT
- Number of commands that the listener can use. MQIACH_COMMAND_COUNT is valid only on Windows.
- MQIACH_LISTENER_CONTROL
- Specifies when the queue manager starts and stops the listener.
- MQIACH_NAME_COUNT
- Number of names that the listener can use. MQIACH_NAME_COUNT is valid only on Windows.
- MQIACH_PORT
- Port number.
- MQIACH_SESSION_COUNT
- Number of sessions that the listener can use. MQIACH_SESSION_COUNT is valid only on Windows.
- MQIACH_SOCKET
- SPX socket on which to listen. MQIACH_SOCKET is valid only on Windows.
- StringFilterCommand (MQCFSF)
- String filter command descriptor. The parameter identifier must be any string type parameter
allowed in ListenerAttrs except MQCACH_LISTENER_NAME.
Use this parameter to restrict the output from the command by
specifying a filter condition. See MQCFSF - PCF string filter parameter for information about using this
filter condition.
If you specify a string filter, we cannot also specify an integer filter using the IntegerFilterCommand parameter.
- TransportType (MQCFIN)
-
Transport protocol
type (parameter identifier: MQIACH_XMIT_PROTOCOL_TYPE).
If you specify this parameter, information is returned relating only to those listeners defined with the specified transport protocol type. If you specify an attribute in the ListenerAttrs list which is valid only for listeners of a different transport protocol type, it is ignored and no error is raised. If you specify this parameter, it must occur immediately after the ListenerName parameter.
If we do not specify this parameter, or if you specify it with a value of MQXPT_ALL, information about all listeners is returned. Valid attributes in the ListenerAttrs list which are not applicable to the listener are ignored, and no error messages are issued. The value can be any of the following values:- MQXPT_ALL
- All transport types.
- MQXPT_LU62
- SNA LU 6.2. MQXPT_LU62 is valid only on Windows.
- MQXPT_NETBIOS
- NetBIOS. MQXPT_NETBIOS is valid only on Windows.
- MQXPT_SPX
- SPX. MQXPT_SPX is valid only on Windows.
- MQXPT_TCP