IBM BPM, V8.0.1, All platforms > Authoring services in Integration Designer > Developing business processes > Building BPEL processes > Defining BPEL process logic

Enabling SCA events to be emitted

You need to enable SCA events to be emitted if you generate a monitor model that monitors SCA events.

To enable SCA events to be emitted, open the administrative console and do the following:


Procedure

  1. Select Application servers > server1.
  2. Open Business Process Choreographer displayed on the right.

  3. Select Business Flow Manager.

  4. Select Custom Properties.

  5. Add a new property named: Compat.SCAMonitoringForBFMAPI and value: true
  6. Set the configuration value for the new property as: value: true.
  7. Save your changes then restart the server.

Defining BPEL process logic


Related concepts:
The building blocks of the BPEL process editor
Dealing with faults in your BPEL process
Work with XPath in the BPEL process editor
Work with micropatterns
Locked activities


Related tasks:
Adding an interface or a reference to a business state machine
Adding a variable to a business state machine
Adding a process application as an activity
Adding an activity to a BPEL process
Defining transactional behavior
Defining timer-driven behavior in a BPEL process
Calling other BPEL processes
Calling business services