Inbound sequences settings
This page displays the collection of inbound sequences for the current scope. Each inbound sequence is used to receive messages that have been transmitted reliably.
To view this page in the console, click one of the paths to this panel. For example Servers > Server Types > WebSphere application servers > server > [Additional Properties] Reliable messaging state > Runtime > Inbound sequences > inbound_sequence_name.
The WS-ReliableMessaging runtime panels are available at many different scopes within the administrative console. See WS-ReliableMessaging - administrative console panels.
Runtime tab
Runtime properties for this object. These properties directly affect the current runtime environment, but are not preserved when that environment is stopped. To preserve runtime property values, change the equivalent property values on the Configuration tab.
General properties
- Sequence identifier
- This URI is the unique identifier for the sequence.
Information Value Required No Data type Text
- Associated application
- The application that is receiving messages from the sequence.
Information Value Required No Data type Text
- WS-Addressing namespace
- The WS-Addressing namespace associated with the sequence.
Information Value Required No Data type Text
- WS-ReliableMessaging namespace
- The namespace that is defined by the version of the WS-ReliableMessaging specification used by the sequence.
Information Value Required No Data type Text
- Target endpoint URI
- The destination to which messages are transmitted.
Information Value Required No Data type Text
- Reply to address
- The WS-Addressing replyTo address used for WS-ReliableMessaging protocol messages.
Information Value Required No Data type Text
- Acknowledgement address
- The address used for WS-ReliableMessaging acknowledgements.
Information Value Required No Data type Text
- Message depth
- The count of messages, held by the reliable messaging layer, that have not yet been transferred.
Information Value Required No Data type Text
- Highest inbound message number
- The highest message number that has been received within the sequence.
Information Value Required No Data type Text
- In-order delivery
- When this parameter is true, messages are dispatched to the application in the order that they were assigned to the sequence.
Information Value Required No Data type Text
Detect and fix problems with WS-ReliableMessaging