Home

 

Channel configuration

 

The following section details the configuration to be performed on the Solaris queue manager to implement the channel described in Figure 1.

The MQSC command to create each object is shown. Either start runmqsc from a UNIX prompt and enter each command in turn, or build the commands into a command file.

Examples are given for connecting WebSphere MQ for Solaris and WebSphere MQ for Windows. If you wish to connect to WebSphere MQ on another platform use the appropriate set of values from the table in place of those for Windows.

The words in bold are user-specified and reflect the names of WebSphere MQ objects used throughout these examples. If you change the names used here, ensure that you also change the other references made to these objects throughout this book. All others are keywords and should be entered as shown.

Configuration worksheet for WebSphere MQ for Solaris
ID Parameter Name Reference Example Used User Value
Definition for local node
A Queue Manager Name   SOLARIS  
B Local queue name   SOLARIS.LOCALQ  
Connection to WebSphere MQ for Windows

The values in this section of the table must match those used in Table 1, as indicated.

C Remote queue manager name A WINNT  
D Remote queue name   WINNT.REMOTEQ  
E Queue name at remote system B WINNT.LOCALQ  
F Transmission queue name   WINNT  
G Sender (SNA) channel name   SOLARIS.WINNT.SNA  
H Sender (TCP/IP) channel name   SOLARIS.WINNT.TCP  
I Receiver (SNA) channel name G WINNT.SOLARIS.SNA  
J Receiver (TCP) channel name H WINNT.SOLARIS.TCP  
Connection to WebSphere MQ for AIX

The values in this section of the table must match those used in Table 1, as indicated.

C Remote queue manager name A AIX  
D Remote queue name   AIX.REMOTEQ  
E Queue name at remote system B AIX.LOCALQ  
F Transmission queue name   AIX  
G Sender (SNA) channel name   SOLARIS.AIX.SNA  
H Sender (TCP) channel name   SOLARIS.AIX.TCP  
I Receiver (SNA) channel name G AIX.SOLARIS.SNA  
J Receiver (TCP) channel name H AIX.SOLARIS.TCP  
Connection to MQSeries for Compaq Tru64 UNIX

The values in this section of the table must match those used in your Compaq Tru64 UNIX system.

C Remote queue manager name A DECUX  
D Remote queue name   DECUX.REMOTEQ  
E Queue name at remote system B DECUX.LOCALQ  
F Transmission queue name   DECUX  
H Sender (TCP) channel name   DECUX.SOLARIS.TCP  
J Receiver (TCP) channel name H SOLARIS.DECUX.TCP  
Connection to WebSphere MQ for HP-UX

The values in this section of the table must match those used in Table 1, as indicated.

C Remote queue manager name A HPUX  
D Remote queue name   HPUX.REMOTEQ  
E Queue name at remote system B HPUX.LOCALQ  
F Transmission queue name   HPUX  
G Sender (SNA) channel name   SOLARIS.HPUX.SNA  
H Sender (TCP) channel name   SOLARIS.HPUX.TCP  
I Receiver (SNA) channel name G HPUX.SOLARIS.SNA  
J Receiver (TCP/IP) channel name H HPUX.SOLARIS.TCP  
Connection to WebSphere MQ for Linux

The values in this section of the table must match those used in Table 1, as indicated.

C Remote queue manager name A LINUX  
D Remote queue name   LINUX.REMOTEQ  
E Queue name at remote system B LINUX.LOCALQ  
F Transmission queue name   LINUX  
G Sender (SNA) channel name   SOLARIS.LINUX.SNA  
H Sender (TCP/IP) channel name   SOLARIS.LINUX.TCP  
I Receiver (SNA) channel name G LINUX.SOLARIS.SNA  
J Receiver (TCP/IP) channel name H LINUX.SOLARIS.TCP  
Connection to WebSphere MQ for iSeries

The values in this section of the table must match those used in Table 1, as indicated.

C Remote queue manager name A AS400  
D Remote queue name   AS400.REMOTEQ  
E Queue name at remote system B AS400.LOCALQ  
F Transmission queue name   AS400  
G Sender (SNA) channel name   SOLARIS.AS400.SNA  
H Sender (TCP) channel name   SOLARIS.AS400.TCP  
I Receiver (SNA) channel name G AS400.SOLARIS.SNA  
J Receiver (TCP) channel name H AS400.SOLARIS.TCP  
Connection to WebSphere MQ for z/OS

The values in this section of the table must match those used in Table 1, as indicated.

C Remote queue manager name A MVS™  
D Remote queue name   MVS.REMOTEQ  
E Queue name at remote system B MVS.LOCALQ  
F Transmission queue name   MVS  
G Sender (SNA) channel name   SOLARIS.MVS.SNA  
H Sender (TCP) channel name   SOLARIS.MVS.TCP  
I Receiver (SNA) channel name G MVS.SOLARIS.SNA  
J Receiver (TCP) channel name H MVS.SOLARIS.TCP  
Connection to MQSeries for VSE/ESA

The values in this section of the table must match those used in your VSE/ESA™ system.

C Remote queue manager name A VSE  
D Remote queue name   VSE.REMOTEQ  
E Queue name at remote system B VSE.LOCALQ  
F Transmission queue name   VSE  
G Sender channel name   SOLARIS.VSE.SNA  
I Receiver channel name G VSE.SOLARIS.SNA  

 

Parent topic:

WebSphere MQ for Solaris configuration


ic14100_


 

Home