Instrumentation facilities codes (X'E6')

 

If an instrumentation facilities reason code occurs that is not listed here, an internal error has occurred. Collect the items listed in Instrumentation facilities problem determination and contact your IBM support center.

00E60008
Explanation:

An internal error has occurred.

System Action:

The function being traced is ended abnormally. The queue manager remains operational.

System Programmer Response:

Collect the items listed in Instrumentation facilities problem determination and contact your IBM support center.

00E60017
Explanation:

This code is an internal code used by the dump formatter.

System Action:

The request is ended abnormally.

System Programmer Response:

Collect the items listed in Instrumentation facilities problem determination and contact your IBM support center.

00E60085, 00E60086, 00E60087, 00E60088, 00E60089
Explanation:

An internal error has occurred.

System Action:

The request is end abnormally.

System Programmer Response:

Collect the items listed in Instrumentation facilities problem determination and contact your IBM support center.

00E60100 through 00E60199
Explanation:

The reason codes X'00E60100' through X'00E60199' are used by the instrumentation facility component (IFC) when a trace event occurs for which IBM service personnel have requested a dump using the IFC selective dump service aid.

System Action:

The agent might be retried or terminated, depending upon the serviceability dump request.

System Programmer Response:

The reason code is issued on the occurrence of a specified trace event. An SVC dump is taken to the SYS1.DUMPxx data set. Problem determination methods depend on the condition that IBM service personnel are attempting to trap.

00E60701
Explanation:

An internal error has occurred.

System Action:

The current execution unit terminates with completion code X'5C6'.

System Programmer Response:

Collect the items listed in Instrumentation facilities problem determination and contact your IBM support center.

00E60702, 00E60703, 00E60704
Explanation:

An internal error has occurred.

System Action:

The current execution unit terminates with completion code X'5C6'.

System Programmer Response:

Collect the items listed in Instrumentation facilities problem determination and contact your IBM support center.

 

Instrumentation facilities problem determination

Collect the following diagnostic items:

  • Console output for the period leading up to the error

  • System dump, if any

  • Printout of SYS1.LOGREC

  • The WebSphere MQ, z/OS, DB2, CICS, and IMS service levels