IBM Tivoli Composite Application Manager for Application Diagnostics, Version 7.1.0.1

CYNP0016W: There is a missing method trace for the end of the request

The problem: The following error message occurs:

CYNP0016W: There is a missing method trace for the end of the request.

The cause: The Publish Server maintains the request stack corresponding to the request on the application server in the same order as they are invoked. If the Publish Server gets the end of the request without the start, this warning message is thrown.

The solution: Take the following steps:

  1. Log on to the Visualization Engine;

  2. Navigate to Administration > Managing Server > System Properties;

  3. Tune the Managing Server by increasing Max Method Records from 10000 (default) to 100000 (100K), 500000 (500K) or 1000000 (1M) in steps if the error persists in the logs.


Parent topic:

Run the Managing Server

+