IBM Tivoli Composite Application Manager for Application Diagnostics, Version 7.1.0.1
Configure the Enterprise Overview display
Use the Enterprise Overview Display settings to set the response time Baseline Indicators and Baseline Definitions. The Baseline Indicator is the percentage above the baseline that you determine to indicate slow or very slow response. The Baseline Definition determines how the baseline is calculated. These thresholds apply to the average of average response times for all servers in the group.To configure the Enterprise Overview display, from the top navigation, click...
Administration | Managing Server | System Properties | Enterprise Overview Display
...and enter the appropriate value for the following properties...
Baseline Indicator Settings The percentage above the baseline that indicates slow or very slow response time. Slow response means the present response time is between 26% and 50% of the baseline; very slow response means the present response time exceeds 50% of the baseline. All averages are over 5 minute intervals. For example: if Indicator 1 is set to 25%, and Indicator 2 is set to 50%, average response times between 125% and 150% of the baseline are considered slow response. Average response times above 150% of the baseline are considered very slow response.
Baseline Definition Settings The method to be used for determining the response time baseline.
Rolling Date Historical response time data for this number of days is averaged to determine the baseline. Fixed Date Baseline is the average response time over the time interval midnight on the start date to 11:59PM on the end date. Fixed Response Time The response time entered in this field will become the response time against which your current response times on the enterprise overview page will be compared.
These properties are actually defined at the group level for the servers once they are added to a group. The group properties take precedence over the system properties. When the response time reaches Indicator 1, an orange indicator will display on the Enterprise Overview page; a red indicator means the response time has exceeded Indicator 2.
Parent topic:
System properties
Related topics
Configure the Data Collection settings
Configure the SNMP network