Many clients producing messages can cause the server to fall behind in processing messages. The flow control parameters can help by slowing down production of messages. Using flow control can help the overall throughput of the system.
Security roles The following roles have read, write, and invoke permission for all non-encrypted attributes and operations in this MBean:
- Deployer
Fully Qualified Interface Name If you use the getMBeanInfo operation in MBeanTypeServiceMBean, supply the following value as this MBean's fully qualified interface name:
weblogic.j2ee.descriptor.wl.FlowControlParamsBean
Factory Methods No factory methods. Instances of this MBean are created automatically.
Attributes
This section describes the following attributes:
FlowControlEnabled
Whether a producer created using a connection factory allows flow control. If true, the associated message producers will be slowed down if a JMS server or a destination reaches its specified upper byte or message threshol.
Privileges Read/Write Type boolean Default Value true
FlowInterval
The adjustment period of time, in seconds, when a producer adjusts its flow from the FlowMaximum number of messages to the FlowMinimum amount, or vice versa.
When a producer is flow controlled, it is slowed down from its FlowMaximum to its FlowMinimum over the specified FlowInterval amount of seconds.
Privileges Read/Write Type int Default Value 60 Minimum value 0 Maximum value 2147483647
FlowMaximum
The maximum number of messages-per-second allowed for a producer that is experiencing a threshold condition. When a producer is flow controlled it will never be allowed to go faster than the FlowMaximum messages per second.
If a producer is not currently limiting its flow when a threshold condition is reached, the initial flow limit for that producer is set to FlowMaximum. If a producer is already limiting its flow when a threshold condition is reached (the flow limit is less than FlowMaximum), then the producer will continue at its current flow limit until the next time the flow is evaluated.
Note: Once a threshold condition has subsided, the producer is not permitted to ignore its flow limit. If its flow limit is less than the FlowMaximum, then the producer must gradually increase its flow to the FlowMaximum each time the flow is evaluated. When the producer finally reaches the FlowMaximum, it can then ignore its flow limit and send without limiting its flow.
Privileges Read/Write Type int Default Value 500 Minimum value 1 Maximum value 2147483647
FlowMinimum
The minimum number of messages-per-second allowed for a producer that is experiencing a threshold condition. This is the lower boundary of a producer's flow limit. That is, WebLogic JMS will not further slow down a producer whose message flow limit is at its FlowMinimum.
When a producer is flow controlled it will never be required to go slower than FlowMinimum messages per second.
Privileges Read/Write Type int Default Value 50 Minimum value 1 Maximum value 2147483647
FlowSteps
The number of steps used when a producer is adjusting its flow from the Flow Maximum amount of messages to the Flow Minimum amount, or vice versa. Specifically, the Flow Interval adjustment period is divided into the number of Flow Steps (for example, 60 seconds divided by 6 steps is 10 seconds per step).
Also, the movement (i.e., the rate of adjustment) is calculated by dividing the difference between the Flow Maximum and the Flow Minimum into steps. At each Flow Step, the flow is adjusted upward or downward, as necessary, based on the current conditions, as follows:
The downward movement (the decay) is geometric over the specified period of time (Flow Interval) and according to the specified number of Flow Steps. (For example, 100, 50, 25, 12.5)
The movement upward is linear. The difference is simply divided by the number of steps.
Privileges Read/Write Type int Default Value 10 Minimum value 1 Maximum value 2147483647
OneWaySendMode
Whether message producers created using this connection factory are allowed to do one-way message sends to improve typical non-persistent, non-transactional messaging performance. When enabled, the associated queue senders and/or topic publishers can send messages without internally waiting for a response from the target destination's host JMS server.
One-way sends are supported only when the connection factory hosting the producer and the JMS server hosting the target destination are targeted to the same WebLogic Server instance. In addition, one-way sends are not supported for higher quality-of-service (QOS) features, such as XA, transacted sessions, persistent messaging, unit-of-order, unit-of-work, distributed destinations, and client-side store-and-forward. If the producer and target destination are in separate domains, or if any of these higher QOS features are detected, then the one-way mode setting will be ignored and standard two-way sends will be used instead.
- Disabled
One-way send is disabled.
- Enabled
One-way send is permitted for queue senders or topic publishers.
- Topic Only
Only topic publishers are permitted to do one-way sends.
Notes:
One-way message sends are disabled if your connection factory is configured with
XA Connection Factory Enabled. This setting disables one-way sends whether or not the sender actually uses transactions.
To benefit from one-way performance, the default
One-Way Send Window Size value must also be configured higher. After every
OneWaySendWindowSize - 1 number of messages, a two-way is used instead of a one-way, so all messages are actually two-way when the
OneWaySendWindowSize = 1.
Privileges Read/Write Type java.lang.String Default Value disabled
OneWaySendWindowSize
Specifies the maximum number of sent messages per window when
One-Way Send Mode is set to allow queue senders and/or topic publishers to make one-way sends. The window size determines when a two-way message is required to regulate the producer before it can continue making additional one-way sends.
To benefit from one-way performance, the default
One-Way Send Window Size value must be configured higher in addition to enabling one-way sends. After every
OneWaySendWindowSize - 1 number of messages, a two-way is used instead of a one-way, so all messages are actually two-way when the
OneWaySendWindowSize = 1.
For more information, see:
Privileges Read/Write Type int Default Value 1 Minimum value 1 Maximum value 2147483647
Operations
This section describes the following operations:
isSet
Return true if the given property has been explicitly set in this bean.
Operation Name "isSet"
Parameters Object [] { propertyName }
where:
propertyName is an object of type
java.lang.String that specifies:
property to check
Signature String [] { "java.lang.String" }
Returns boolean
Exceptions
java.lang.IllegalArgumentException
IllegalArgumentException if propertyName is not a recognized property
unSet
Restore the given property to its default value.
Operation Name "unSet"
Parameters Object [] { propertyName }
where:
propertyName is an object of type
java.lang.String that specifies:
property to restore
Signature String [] { "java.lang.String" }
Returns void
Exceptions
java.lang.IllegalArgumentException
UnsupportedOperationException if called on a runtime implementation.