CTGDJH001E
Connector could not return entry because an unknown class type was encountered: ''object type''
Explanation:
The SNMP Connector was trying to return an entry but the class type was unknown.
Operator response:
No action is required.
CTGDJH002I
Connector listening for SNMP traps only.
Explanation:
This is an informational message only.
CTGDJH003E
The 'snmpOID' parameter must be set to use the SNMP Connector.
Explanation:
The required parameter snmpOID was not specified in the SNMP Connector.
Operator response:
Specify the snmpOID parameter in the Connector.
CTGDJH004I
Getting the next SNMP entry. Comparing response OID ''OID'' of the entry with configured walkOID parameter ''OID''.
Explanation:
This is an informational message only.
CTGDJH005E
Connector could not get next SNMP entry because a bad PDU was received from the SNMP Server. Error occurred: exception
Explanation:
The SNMP Connector was trying to retrieve the next entry for the SNMP server but failed because a bad PDU was received.
Operator response:
Verify that the SNMP Server the Connector is receiving data from is still running.
CTGDJH006I
Ignoring unsupported link criteria name: ''link criteria''.
Explanation:
This is an informational message only.
CTGDJH007I
Search criteria for entry search: OID=''OID'' version=''version'' host=''hostname'' port=''port number''.
Explanation:
This is an informational message only.
CTGDJH008E
Connector could not add entry because set request to SNMP Server failed. Error occurred: error message
Explanation:
The SNMP Connector was trying to add an entry to the SNMP server but failed because the set request failed.
Operator response:
Verify that the SNMP Server the Connector trying to add the entry to is still running and that the entry being added is valid. Also, review the message from SNMP Server for additional detail on why the error occurred.
CTGDJH009I
Will send request to get entry with OID ''OID''.
Explanation:
This is an informational message only.
CTGDJH010E
Connector could not get next SNMP entry because a bad PDU was received from the SNMP Server. Error occurred: exception
Explanation:
The SNMP Connector was trying to retrieve the next entry for the SNMP server but failed because a bad PDU was received.
Operator response:
Verify that the SNMP Server the Connector is receiving data from is still running.
CTGDJH011I
Empty queue, waiting for data for ''number of seconds'' seconds.
Explanation:
This is an informational message only.
CTGDJH012I
Empty queue, waiting for data with no timeout value.
Explanation:
This is an informational message only.
CTGDJH013I
Trap received: trap.
Explanation:
This is an informational message only.
CTGDJH101I
Initializing with the provided java.net.DatagramPacket object.
Explanation:
This is an informational message only.
CTGDJH102E
The 'udp.port' parameter must be set to use the SNMP Server Connector.
Explanation:
The required parameter udp.port was not specified in the SNMP Server Connector.
Operator response:
Specify the udp.port parameter in the Connector.
CTGDJH103E
Invalid 'udp.port' parameter set in the the SNMP Server Connector: ''parameter value''.
Explanation:
The required parameter udp.port was specified in the JMX Connector but was set to an invalid value.
Operator response:
Specify a valid value for the udp.port parameter in the Connector.
CTGDJH104I
Waiting for SNMP packets on UDP port ''port number''.
Explanation:
This is an informational message only.
CTGDJH105I
Connector terminated by external request.
Explanation:
This is an informational message only.
CTGDJH106I
Connector terminating by external request.
Explanation:
This is an informational message only.
CTGDJH107I
Receiving Connection from ''hostname''.
Explanation:
This is an informational message only.
CTGDJH108I
Receiving Connection from ''hostname''.
Explanation:
This is an informational message only.
CTGDJH109I
Ignoring add request for community ''community name''.
Explanation:
This is an informational message only.
CTGDJH110I
Response PDU on add entry request i ''PDU''.
Explanation:
This is an informational message only.
CTGDJH111I
The SNMP error code ''error code'' has an illegal value. The error code value will be changed to 5.
Explanation:
This is an informational message only.
CTGDJH112I
Terminate server request received.
Explanation:
This is an informational message only.
CTGDJH113I
Creating dummy connection using IP Address ''IP Address'' and port ''port number''.
Explanation:
This is an informational message only.
CTGDJH114W
Encountered an IOException on unblocking the SNMP Server Connector's server socket: exception
Explanation:
See message.
Operator response:
No action required.
CTGDJH115I
SNMP Server Connector is already terminating. Not sending termination request.
Explanation:
This is an informational message only.
CTGDJH116I
Sending termination request to SNMP Server Connector.
Explanation:
This is an informational message only.
CTGDJH117W
Unable to add one or more attributes to the entry. Exception occurred: exception
Explanation:
See message.
Operator response: