CTGDIY001E
Unable to get next entry. No AssemblyLine to execute.
Explanation:
The AssemblyLine Connector could not get the next entry because there were no AssemblyLines to execute/retrieve.
Operator response:
The method initialize should be invoked first.
CTGDIY002E
Expecting com.ibm.di.entry.Entry, object found Java class name.
Explanation:
If the work Entry of the adapted Assembly Line has an attribute named conn, that attribute must contain values of type com.ibm.di.entry.Entry only.
Operator response:
Verify the logic of the adapted Assembly Line.
CTGDIY003I
Computed modes for Connector name :
Explanation:
This is an informational message only.
CTGDIY004I
Operations for Assembly Line name :
Explanation:
This is an informational message only.
CTGDIY005I
Standard modes recorded :
Explanation:
This is an informational message only.
CTGDIY006E
Unable to connect to server/config: server host / Config instance id.
Explanation:
Cannot find the specified configuration instance on the specified TDI server.
Operator response:
Verify that the specified server is running. Verify that the specified configuration is running on the specified server.
CTGDIY007I
Performing operation: operation name, work Entry: entry name.
Explanation:
This is an informational message only.
CTGDIY008I
Operation operation name returned Java object.
Explanation:
This is an informational message only.
CTGDIY101E
Unable to select AssemblyLine operation. The remote Config ''Config name'' cannot be found on server ''server name''.
Explanation:
The configuration instance specified in the AssemblyLine Function Component's Config parameter could not be found on the remote server.
Operator response:
Verify the specified Config parameter exists on the remote server.
CTGDIY102E
Unable to select AssemblyLine operation. Connection to server ''server name'' cannot be obtained.
Explanation:
The remote server instance specified in the AssemblyLine Function component's server parameter may not be currently active.
Operator response:
Verify the specified server instance [hostname:port] combination is active on the remote server and then try to establish a connection again.
CTGDIY103E
No server configured.
Explanation:
The Server configuration parameter is required for the query configuration operation to work.
Operator response:
Enter a valid remote TDI server information [hostname:port] in the AssemblyLine Function Component server parameter fields and then perform the query configuration operation.
CTGDIY104E
Unable to retrieve initialized schema. The remote Config ''Config name'' cannot be found on server ''server name''.
Explanation:
The configuration instance specified in the AssemblyLine Function Component's Config parameter could not be found on the remote server.
Operator response:
Verify the specified Config parameter exists on the remote server.
CTGDIY105E
Unable to select AssemblyLine. The remote Config ''Config name'' cannot be found on server ''server name''.
Explanation:
The configuration instance specified in the AssemblyLine Function Component's Config parameter could not be found on the remote server.
Operator response:
Verfiy the specified Config parameter exists on the remote server.
CTGDIY106E
Unable to retrieve initialized schema. Connection to server ''server name'' cannot be obtained.
Explanation:
The remote server instance specified in the AssemblyLine Function component's server parameter may not be currently active.
Operator response:
Verify the specified server instance [hostname:port] combination is active on the remote server and then try to establish a connection again.
CTGDIY107E
Unable to select AssemblyLine. Connection to server ''server name'' cannot be obtained.
Explanation:
The remote server instance specified in the AssemblyLine Function component's server parameter may not be currently active.
Operator response:
Verify the specified server instance [hostname:port] combination is active on the remote server and then try to establish a connection again.
CTGDIY108I
Waiting 2 seconds for remote AssemblyLine to complete: ''AssemblyLine Name''.
Explanation:
This is an informational message only.
CTGDIY109E
The Config instance not specified for server ''server name''.
Explanation:
See message.
Operator response:
Verfiy the specified Config parameter exists on the remote server.
CTGDIY110E
The 'assemblyLine' parameter must be set to use the AssemblyLine Function Component.
Explanation:
The required parameter assemblyLine was not specified in the AssemblyLine Function Component.
Operator response:
Specify the assemblyLine parameter in the Function Component.
CTGDIY111E
Unable to parse attributes in the entry. Encountered an unknown TCB parameter ''parameter name''.
Explanation:
There is no dot symbol in the attribute name.
Operator response:
Check the attribute names prefix must be '$tcb.'.
CTGDIY112E
Exception occurred while retrieving configuration: exception
Explanation:
Cannot get the specified configuration.
Operator response:
Contact IBM support.
CTGDIY113W
Warning: Cannot run local AssemblyLines.
Explanation:
This is an informational message only.