Service facilities codes (X'F1')
- 00F10001, 00F10002, 00F10003, 00F10004, 00F10005, 00F10006, 00F10007, 00F10008, 00F10009, 00F10010, 00F10011, 00F10012, 00F10013, 00F10014, 00F10015, 00F10016, 00F10017, 00F10018
-
An internal error has been detected in the CSQ1LOGP log print utility.
- System action
-
A dump is requested. The utility ends abnormally with completion code X'5C6'.
- System programmer response
-
Collect the following diagnostic items and contact the IBM
support center:
- Utility report output
- System dump resulting from the error, if any
- The WebSphere MQ, z/OS, Db2, CICS, and IMS service levels
- 00F10100
-
An internal error has been detected in the CSQ1LOGP log print utility.
- System action
-
A dump is requested. The utility ends abnormally with completion code X'5C6'.
- System programmer response
-
Resubmit the job.
Contact the IBM support center if the problem persists.
- 00F10101
-
The stand-alone log read function returned an invalid RBA. See the explanation for message CSQ1211E.
- System action
-
A dump is requested. The utility ends abnormally with completion code X'5C6'.
- System programmer response
-
If you determine that the data set is a log data set and that it is not damaged, contact the IBM support center.
Parent topic: IBM MQ for z/OS codes