Coupling Facility codes (X'C5')
If a coupling facility reason code occurs that is not listed here, an internal error has occurred. Collect the following diagnostic items and contact the IBM support center. Restart the queue manager if necessary.
Diagnostics
- A description of the actions that led to the error or, if applicable, either a listing of the application program or the input string to a utility program that was being run at the time of the error.
- The console output for the period leading up to the error.
- The queue manager job log.
- The system dump resulting from the error.
- If we are using CICS, the CICS transaction dump output.
- Appropriate IBM MQ, z/OS, Db2, CICS, and IMS service levels.
- If we are using the IBM MQ Operations and Control panels, the ISPF panel name.
- A dump of the coupling facility structure.
- 00C50006
-
A backup or recovery of a CF structure failed because the queue manager is not connected to a Db2 subsystem.
- System action
-
CF structure backup or recovery processing is terminated.
- System programmer response
-
Configure the Db2 subsystem so that the queue manager can connect to it.
- 00C50012
-
CF structure processing failed, because the CF structure became full during the action.
- System action
-
CF structure processing is terminated.
- System programmer response
-
Increase the size of the CF structure.
- 00C50014
-
An unexpected reason code was returned by the Db2 subsystem that the queue manager is connected to.
- System action
-
The current operation is terminated.
- System programmer response
-
Investigate the cause of the error, as reported in the preceding messages.
- 00C50050
-
The CF structure is being recovered and cannot be used until the recovery is complete.
- System action
-
Processing of the command is terminated.
- System programmer response
-
Wait for the recovery of the structure to complete, then reissue the command. Use the DISPLAY CFSTATUS command to view the status of the CF structures.
- 00C50064
-
A backup or recovery of a CF structure failed either because the installation and customization options chosen for IBM MQ do not allow the queue manager to use structures at the required level, or because the level of the structure is not supported by the current command level.
- System action
-
CF structure backup or recovery processing is terminated.
- 00C5004F
-
This reason code is issued in message CSQM090E when a command has failed. It indicates that a request has been issued for a CF structure, but the request cannot be performed, as explained in the accompanying more specific message.
- Severity
-
4
- System action
-
The command is ignored.
- System programmer response
-
Refer to the description of the accompanying message.
- 00C5005B
-
CF structure recovery failed because an error occurred when reading the BSDS of another queue manager in the queue sharing group.
- System action
-
CF structure recovery processing is terminated.
- System programmer response
-
Check the log for recovery log manager messages that indicate the reason for the error.
- 00C50D00
-
A backup of a CF structure failed because a required SMDS data set is not available.
- System action
-
CF structure backup processing is terminated.
- System programmer response
-
Ensure that all SMDS data sets used for the CF structure are available, then reissue the backup command. A RECOVER CFSTRUCT command can be used to restore these data sets if this is required.
- 00C51001, 00C51004, 00C51005, 00C51006, 00C5100A, 00C51019, 00C5101A, 00C5101B, 00C5101C, 00C5001D
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51021, 00C51022, 00C51023, 00C51024, 00C50025, 00C51026, 00C51027, 00C51028, 00C51029, 00C5002A, 00C5102B, 00C5102C, 00C5102D, 00C5102E, 00C5002F
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C5102F
-
The queue manager failed to connect to the administration structure.
- System action
-
The current execution unit terminates with completion code X'5C6', and the queue manager attempts to connect to the administration structure if it becomes available again. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Investigate the configuration for the administration structure. This abend code might be seen if the queue manager is running on an LPAR with no connectivity to the administration structure, or if the administration structure has been encrypted, but the LPAR does not have access to a cryptographic coprocessor.
- 00C50030, 00C51031, 00C51032, 00C51033, 00C51034, 00C50035, 00C51036, 00C51037, 00C51038, 00C51039, 00C5003A, 00C5103A, 00C5103B, 00C5103C, 00C5103D, 00C5103E, 00C5003F
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C50040, 00C51041, 00C51042, 00C51043, 00C51044, 00C50045, 00C51046, 00C51047
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager may terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51051, 00C51052, 00C51053, 00C51054, 00C50055, 00C51056
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager may terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51090, 00C51092, 00C51093
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51094, 00C51095, 00C51096, 00C51097
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
- 00C510A1, 00C510A2, 00C510A3, 00C510A4, 00C500A5, 00C510A6, 00C510A7, 00C510A8, 00C510A9, 00C500AA
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C510AB
-
The CF structure has failed or connection to it has been lost.
- System action
-
This might be issued in response to a command, in which case processing of the command is terminated. Otherwise, the current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Restart the queue manager if necessary. Recover the structure; if the error occurred in response to a command, reissue it.
- 00C510AC, 00C510AD
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51100, 00C51101, 00C51102, 00C51103, 00C51104, 00C51105, 00C51106, 00C51107, 00C51108, 00C51109, 00C5110A, 00C5110B, 00C5110C, 00C5110D, 00C5110E, 00C5110F
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager may terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51110, 00C51111, 00C51112, 00C51113, 00C51114, 00C51115, 00C51116, 00C51117, 00C51118, 00C51119, 00C5111A, 00C5111B, 00C5111C, 00C5111D, 00C5111E, 00C5111F
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51120, 00C51121, 00C51122, 00C51123, 00C51124, 00C51125, 00C51126, 00C51127, 00C51128, 00C51129, 00C5112A, 00C5112B, 00C5112C, 00C5112D, 00C5112E, 00C5112F
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51130, 00C51131, 00C51132, 00C51133, 00C51134, 00C51135, 00C51136, 00C51137, 00C51138, 00C51139, 00C5113A, 00C5113B, 00C5113C, 00C5113D, 00C5113E, 00C5113F
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager may terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51140, 00C51141, 00C51142, 00C51143, 00C51144, 00C51145, 00C51146, 00C51147, 00C51148, 00C51149, 00C5114A, 00C5114B, 00C5114C, 00C5114D, 00C5114E, 00C5114F
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager may terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51150, 00C51151, 00C51152, 00C51153, 00C51154, 00C51155, 00C51156, 00C51157, 00C51158, 00C51159, 00C5115A, 00C5115B, 00C5115C, 00C5115D, 00C5115E, 00C5115F
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51160, 00C51161, 00C51162, 00C51163, 00C51164, 00C51165, 00C51166, 00C51167, 00C51168, 00C51169, 00C5116A, 00C5116B, 00C5116C, 00C5116D, 00C5116E, 00C5116F
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51170, 00C51171, 00C51172, 00C51174, 00C51175, 00C51176, 00C51177, 00C51178, 00C51179, 00C5117A, 00C5117B, 00C5117C, 00C5117D, 00C5117E, 00C5117F
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51173
-
An internal error has occurred.
- System action
-
The internal task performing recovery of a CFSTRUCT terminates with completion code x'5C6'.
- System programmer response
-
This error is often, but not exclusively, associated with space issues in the coupling facility.
Ensure that sufficient space is available in the cfstructure.
A common source of error is that the INITSIZE and SIZE values do not match in the CFRM policy. During normal use, the structure has expanded through AUTOALTER processing and the structure backup being restored reflects this size.
However, a new structure has been allocated with the INITSIZE attribute that is too small.
If storage issues are not indicated, then collect the items listed in Diagnostics and contact the IBM support center.
- 00C51180, 00C51181, 00C51182, 00C51184, 00C51185, 00C51186, 00C51187, 00C51188, 00C51189, 00C5118A, 00C5118B, 00C5118C, 00C5118D, 00C5118E, 00C5118F
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager may terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C51183
-
An internal error has occurred.
- System action
-
The internal task performing recovery of a CFSTRUCT terminates with completion code x'5C6'.
- System programmer response
-
This error is often, but not exclusively, associated with space issues in the coupling facility.
Ensure that sufficient space is available in the cfstructure.
A common source of error is that the INITSIZE and SIZE values do not match in the CFRM policy. During normal use, the structure has expanded through AUTOALTER processing and the structure backup being restored reflects this size.
However, a new structure has been allocated with the INITSIZE attribute that is too small.
If storage issues are not indicated, then collect the items listed in Diagnostics and contact the IBM support center.
- 00C51190, 00C51191, 00C51192, 00C51193, 00C51194, 00C51195, 00C51196, 00C51197, 00C51198, 00C51199, 00C5119A, 00C5119B, 00C5119C, 00C5119D, 00C5119E, 00C5119F
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager may terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C511A0, 00C511A1, 00C511A2, 00C511A3, 00C511A4, 00C511A5, 00C511A6, 00C511A7, 00C511A8, 00C511A9, 00C511AA, 00C511AB, 00C511AC, 00C511AD, 00C511AE, 00C511AF
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager may terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C511B0, 00C511B1, 00C511B2, 00C511B3, 00C511B4, 00C511B5, 00C511B6, 00C511B7, 00C511B8, 00C511B9, 00C511BA, 00C511BB, 00C511BC, 00C511BD, 00C511BE, 00C511BF
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager may terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C511C0, 00C511C1, 00C511C2, 00C511C3, 00C511C4, 00C511C5, 00C511C6, 00C511C7, 00C511C8, 00C511C9, 00C511CA, 00C511CB, 00C511CC, 00C511CD, 00C511CE, 00C511CF
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager may terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C511D0, 00C511D1, 00C511D2, 00C511D3, 00C511D4, 00C511D5, 00C511D6, 00C511D7, 00C511D8, 00C511D9, 00C511DA, 00C511DB, 00C511DC, 00C511DD, 00C511DE, 00C511DF
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C511E0, 00C511E1, 00C511E2, 00C511E3, 00C511E4, 00C511E5, 00C511E6, 00C511E7, 00C511E8, 00C511E9, 00C511EA, 00C511EB, 00C511EC, 00C511ED, 00C511EE, 00C511EF
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C511F0, 00C511F1, 00C511F2, 00C511F3, 00C511F4, 00C511F5, 00C511F6, 00C511F7, 00C511F8, 00C511F9, 00C511FA, 00C511FB, 00C511FC, 00C511FD, 00C511FE, 00C511FF
-
An internal error has occurred.
- System action
-
The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.
- System programmer response
-
Collect the items listed in Diagnostics and contact the IBM support center.
Restart the queue manager if necessary.
- 00C53000
-
The queue manager cannot use the administration structure because its size is less than the minimum that IBM MQ requires.
- System action
-
The queue manager terminates with completion code X'6C6'.
- System programmer response
-
Increase the size of the admininstration structure. See message CSQE022E for more information.
- 00C53001
-
The queue manager has detected a mismatch between the queue sharing group creation timestamp in the Db2 tables and the creation timestamp associated with the structure name in message CSQE029E.
- System action
-
The queue manager terminates, a record is written to SYS1.LOGREC and a dump is taken.
- System programmer response
-
Verify the queue manager, queue sharing group and data-sharing group configuration and determine whether a queue manager has configured to connect to a different Db2 data-sharing group.
If the queue manager and queue sharing group configuration is correct then the structure should be deallocated. Having verified that there are only failed-persistent connections remaining to the structure, deallocate it with the z/OS commandSETXCF FORCE,STRUCTURE,STRNAME=ext-struc-name
(In this command, ext-struc-name is formed by prefixing the IBM MQ structure name from message CSQE029E with the queue sharing group name.)
- 00C53002
-
The queue manager cannot use the administration structure because the administration structure is full and remains full despite repeated attempts to wait for space to become available.
- System action
-
The queue manager terminates with completion code X'5C6'.
- System programmer response
-
Increase the size of the administration structure. See message CSQE038E for more information.
Parent topic: IBM MQ for z/OS codes