2131 (0853) (RC2131): MQRC_ADAPTER_DEFS_ERROR


Explanation

On an MQCONN call, the subsystem definition module (CSQBDEFV for batch and CSQQDEFV for IMS ) does not contain the required control block identifier.

This reason code occurs only on z/OSĀ®.


Completion code

MQCC_FAILED


Programmer response

Check your library concatenation. If this is correct, check that the CSQBDEFV or CSQQDEFV module contains the required subsystem ID.