IBM Tivoli Composite Application Manager for Application Diagnostics, Version 7.1.0.1
WAS fails to start on IBM i 6.1
The following content provides solutions when WAS fails to start on IBM i 6.1.
WAS fails to start and error messages are displayed in log file
The problem: WAS fails to start on IBM i 6.1
The symptom: You may find the following error messages in the data collector installation log file:
INFO Executing:UPDSRVPGM SRVPGM(QGPL/AM) MODULE(*NONE) INFO ID: CPF5CA6 INFO Text: Program or Service Program not at correct level for update request. INFO Severity: 40 INFO ID: CPF5CE2 INFO Text: Unexpected error occurred during program or service program update. INFO Severity: 40The solution: You can choose either of the following methods to solve this problem:
- Remove and reinstall the data collector after changing the IBM i 6.1 system value QFRCCVNRST to 2.
- Run the following commands on IBM i 6.1 system:
DLTSRVPGM SRVPGM(QGPL/AM) RSTOBJ OBJ(AM) SAVLIB(QGPL) DEV(*SAVF) OBJTYPE(*SRVPGM) SAVF(QGPL/AMV5R416) FRCOBJCVN(*YES) RSTLIB(QGPL) UPDSRVPGM SRVPGM(QGPL/AM) MODULE(*NONE) DLTSRVPGM SRVPGM(QGPL/AM_SUN_16) MOV OBJ('/QSYS.LIB/QGPL.LIB/AM.SRVPGM') TOOBJ('/QSYS.LIB/QGPL.LIB/AM_SUN_16.SRVPGM') STROBJCVN OPTION(*CHECK) LIB(qgpl), it said SJITI.SRVPGM need convertion. STROBJCVN OPTION(*CONVERT) LIB(QGPL) STROBJCVN OPTION(*CHECK) LIB(QTIVTMTP), it said JVMPI.SRVPGM need convertion. STROBJCVN OPTION(*CONVERT) LIB(QTIVTMTP) STROBJCVN OPTION(*CHECK) LIB(QTIVCCGTS)
WAS fails to start on IBM i 6.1 when you do not have the authority to use API from QSYS/QPMLPMGT
The problem: WAS fails to start on iSeries 6.1 when you do not have the required authority to use API from QSYS/QPMLPMGT.
The reason: Inadequate authority.
The solution: Run the following command:
GRTOBJAUT OBJ(QSYS/QPMLPMGT) OBJTYPE(*SRVPGM) USER(*public) AUT(*use)
Parent topic:
IBM i systems