IBM Tivoli Composite Application Manager for Application Diagnostics, Version 7.1.0.1

Cannot call the IBM Tivoli Monitoring Client after reconfiguring data collector

The problem: After reconfiguring data collector, the information relating to the IBM Tivoli Monitoring Client is no longer the same as that in DC_home/runtime/server_instance.

The reason: When you reconfigure the data collector it records the information relating to IBM Tivoli Monitoring Client that was set when you configured the data collector for the first time. If the information relating to the monitoring agent and TTAS in DC_home/runtime/server_instance is modified manually after the first configuration then the information displayed when you reconfigure the data collector will be different from that in the DC_home/runtime/server_instance.

The solution: Manually change the information relating to IBM Tivoli Monitoring Client in DC_home/runtime/server_instance to match your installation.


Parent topic:

All platforms

+