IBM Tivoli Composite Application Manager for Application Diagnostics, Version 7.1.0.1
KYNM001E KYNALSRD: SERVICE=IXGCONN(CONNECT) FOR LOGSTREAM
The problem: The following messages show up at startup in RKLVLOG for Tivoli Enterprise Monitoring Agent for ITCAM Agent for WebSphere Applications on z/OS:
KYNM001E KYNALSRD: SERVICE=IXGBRWSE(END) FOR LOGSTREAM=WAS.ERROR.LOG FAILED WITH RC=8, REASON=0000082D, DEBUG1=, DEBUG2= KYNM001E KYNALSRD: SERVICE=IXGCONN(CONNECT) FOR LOGSTREAM=WAS.ERROR.LOG FAILED WITH RC=4, REASON=00000407, DEBUG1=, DEBUG2= (0000-C8376623:kynlogscr.cpp,204,"KynWasLogScrapper::getEntries") ERROR: kynalsrd(G) failed (rc 8, status 84D0000)The cause: Tivoli Enterprise Monitoring Agent for ITCAM Agent for WebSphere Applications on z/OS expects the WebSphere log stream to be defined and set with the name in the WebSphere variables. Check the SYSOUT file for the z/OS WebSphere task for this setting:
ras_log_logstreamName: Not Setorras_log_logstreamName: WAS610.ERROR.LOGIf the value is "Not Set", the preceding messages is displayed.The solution: Create the WebSphere log stream and assign the variable.
Parent topic:
z/OS systems