IBM Tivoli Monitoring > Version 6.3 Fix Pack 2 > Installation Guides > Installation Guide > Tivoli Data Warehouse solutions: common procedures > Tuning the performance of the Warehouse Proxy
IBM Tivoli Monitoring, Version 6.3 Fix Pack 2
Work queue
The work queue consists of a single queue instance and a configurable number of worker threads that run work placed on it.
There are two primary configuration parameters that you can set. You can set these parameters in the KHDENV file on Windows or the hd.ini file on Linux and UNIX before starting the Warehouse Proxy.
- KHD_QUEUE_LENGTH
- The length of the KHD work queue. This is an integer that identifies the maximum number of export work requests that can be placed on the work queue before the work queue begins rejecting requests. The default value is 1000. Setting this value to 0 means that the work queue has no limit.
- KHD_EXPORT_THREADS
- The number of worker threads exporting data to the database. The default value is 10.
Parent topic:
Tuning the performance of the Warehouse Proxy