IBM Tivoli Monitoring > Version 6.3 Fix Pack 2 > Installation Guides > Installation Guide > Set up event forwarding to Netcool/OMNIbus > Installation and configuration > Configure the hub monitoring server to forward events

IBM Tivoli Monitoring, Version 6.3 Fix Pack 2


Control event forwarding rate

The om_tec.config file controls the forwarding of events from IBM Tivoli Monitoring to IBM Tivoli Netcool/OMNIbus.

This file contains the following parameter:

BufferFlushRate=events_per_minute

Specifies the number of events that are sent per minute when the adapter has reestablished its connection to the Netcool/OMNIbus Probe for Tivoli EIF. Once the adapter has recovered the lost connection, if there are events in the buffer, the events are sent at this rate per minute. The default value is 0, meaning all events are sent in one burst.
If your environment can have many open situation events, you might want to adjust this parameter to control the rate at which events are sent to the probe. To edit this file and change this parameter:

Restart the hub monitoring server after completing these steps:


Parent topic:

Configure the hub monitoring server to forward events

+

Search Tips   |   Advanced Search