IBM Tivoli Monitoring > Version 6.3 Fix Pack 2 > Installation Guides > Installation Guide > Set up event forwarding to Netcool/OMNIbus > Customize Event Integration > Customize how the IBM Tivoli Monitoring OMNIbus triggers handle event status updates from the monitoring servers
IBM Tivoli Monitoring, Version 6.3 Fix Pack 2
Edit the eventcmd procedure
This section lists possible modifications to the eventcmd procedure.
The eventcmd procedure in the <event_sync_install_dir>/omnibus/itm_proc.sql file might also need the following modifications:
- The value of the executable variable must not contain any spaces. If the Situation Update Forwarder was installed in a directory with spaces, change the executable variable setting from $EVENTCMD to a path for the eventcmd.bat file that does not contain spaces, for example, on Windows: C:\Progra~1\IBM\SitForwarder\omnibus\eventcmd.bat.
- Change the host variable to reflect the actual host name on which the Object Server is running.
- You might have to change the user and group variables from the default settings if the executable cannot be run as root.
Parent topic:
Customize how the IBM Tivoli Monitoring OMNIbus triggers handle event status updates from the monitoring servers