DSPLIND (Display Line Description) Command Description

DSPLIND Command syntax diagram

Purpose

The Display Line Description (DSPLIND) command displays a line description. Output is directed to a display or a spooled printer file as indicated by the OUTPUT parameter and job type.

Required Parameter

LIND
Specifies the name of the line description to be displayed.

Optional Parameters

OUTPUT
Specifies whether the output from the command is shown at the requesting workstation or printed with the job's spooled output. More information on this parameter is in commonly used parameters.

*: Output requested by an interactive job is shown on the display. Output requested by a batch job is printed with the job's spooled output.

*PRINT: The output is printed with the job's spooled output.

OPTION
Specifies the panels to be displayed.

*ALL: All panels that apply to this specific line type are displayed.

*BASIC: The basic displays that apply to this line type are shown, but additional information displays are not shown.

*SWTNWILST: The switched network interface list panels that apply to this line are displayed.

*CTL: The attached nonswitched controller list panels for this line are displayed.

*SWTCTLLST: The switched controller list panels that apply to this line are displayed.

*ACTSWTCTL: The active switched controller list panels that apply to this line are displayed.

*SSAP: The source service access point panels for this token-ring or Ethernet line are displayed.

*GRPADR: The group address panels for this Ethernet line are displayed.

*FCNADR: The functional address panels for this token-ring are displayed.

*EORTBL: The end-of-record table panels for this asynchronous line are displayed.

*LGLCHLE: The logical channel entries for this X.25 line are displayed.

*APPN: The advanced peer-to-peer networking (APPN) values for this line are displayed.

*PHYCHAR: The information concerning the physical characteristics of an asynchronous line is displayed.

*THRESHOLD: The information concerning the threshold values of an IDLC line is displayed.

*TMRRTY: The timer and retry values for this line are displayed.

Example for DSPLIND

DSPLIND LIND(LINE21)

This command displays information about the line description named LINE21. The information is shown on the work station display from which the command was submitted. If the command is entered from a batch job, the output from the display is printed with the job's spooled output.

Error messages for DSPLIND

*ESCAPE Messages

CPF2601
Line description &1 not found.
CPF2625
Not able to allocate object &1.
CPF2626
Line description previously deleted.
CPF2634
Not authorized to object &1.
CPF268A
&1 not valid for line &2.
CPF2779
Line description &1 has been damaged.