Verifying OptiConnect software installation
After you install OptiConnect software, follow this procedure to verify that the installation is successful.
- Run the Check Product Option (CHKPRDOPT) command to ensure that the OptiConnect code and objects have been installed correctly.
- Enter STRSBS QSOC/QSOC on all systems to start the OptiConnect QSOC subsystem.
- Enter DSPMSG *SYSOPR on all systems to display the messages that were issued when the QSOC subsystem was started. The following messages are displayed after a successful initiation of the OptiConnect connection manager:
Subsystem QSOC in library QSOC starting. Subsystem QSOC started. OptiConnect connection manager started at mm/dd/yy hh:mm:ss. OptiConnect connected to SYSTEMA using SOC01 at mm/dd/yy hh:mm:ss. OptiConnect connected to SYSTEMB using SOC02 at mm/dd/yy hh:mm:ss.The number of messages (and adapter types within the messages) that you see depend on the following factors:
- Your hardware configuration
- The systems to which you are connected
- The systems that have started the OptiConnect subsystem
- Enter VFYOPCCNN to begin the installation verification. This ensures system-to-system connection in the cluster. Check your job log for the completion message OptiConnect verification test completed with no errors.
- Enter QSOC/WRKOPCACT to check the OptiConnect activity on the systems in the cluster. You should see activity as a result of the Verify OptiConnect Connection (VFYOPCCNN) procedure. VFYOPCCNN causes the system to act as a client to each of the other systems in the network.
- Enter WRKHDWRSC TYPE(*CSA) to confirm that the hardware connections are operational and to show the operational status of the bus receiver cards. TYPE(*CSA) displays a resource for each remote system that had, at some point, an operational connection to the system on which you are entering the command.
Parent topic:
Installing OptiConnectRelated tasks
Installing OptiConnect software