Offset from UTC was incorrectly set during i5/OS installation

 

If the offset from UTC (QUTCOFFSET) system value was not set correctly during the installation, the initial time zone value for your system might not be correct.

If you set the time zone before the installation of the i5/OS® operating system, the offset from UTC is set according to the time zone you specified. If you set the time zone during an initial program load (IPL), the offset from UTC is set according to the time zone you specified during the IPL. Otherwise, the offset from UTC is determined by the initial time zone value.

This troubleshooting topic assumes that you did not set the time zone (QTIMZON) system value before installation or during an IPL.

The offset might be incorrect if any of the following conditions exist:

Recovery steps

The offset from Coordinated Universal Time (QUTCOFFSET) system value is derived from the time zone (QTIMZON) system value. Therefore, if the time zone is not correct, the offset is not correct either. After the time zone system value is set correctly, the offset from UTC is correct.

To troubleshoot this situation...

  1. Verify the time zone properties.

  2. Verify the time system values.

 

Parent topic:

Troubleshooting time management