SQL0114 - Relational database
amp;1 not the same as current amp;2 server
Update the iSeries Access ODBC Relational Database Directory Entry.
Probable cause:
It is likely that the system name is not in the Remote Database Directory. Run the Add Relational Database Directory Entry command:
ADDRDBDIRE RDB(SYSNAME) RMTLOCNAME(*LOCAL)
In this above example, SYSNAME is the name of your system's Default Local Location name (as specified in the DSPNETA command).
Another common cause for this error is a period (.) in a table or library name. Although valid in naming conventions, in order to use it within an SQL statement, enclose the name within double quotes. A short term circumvention may be to build a logical file over the desired physical file, using the SQL naming syntax.
Related concepts
SQL0104 - Token &1 was not valid. Valid tokens: &2