Network Deployment (Distributed operating systems), v8.0 > Reference > Administrator best practices
Alarm Manager counters
Use this page as a reference for properties of alarm manager counters.
Counters for this category contain information for the Alarm Manager.
Related
PMI data organization
Counter definitions
Alarm Manager counter definitions.. This table displays properties for Alarm Manager counters.
Name Key ID values Description Granularity Type Level Overhead AlarmsCreatedCount alarmManagerModule.numCreates.name 1 The total number of alarms created by all asynchronous scopes for this WorkManager Per WorkManager CountStatistic All High AlarmsCancelledCount alarmManagerModule.numCancelled.name 2 The number of alarms cancelled by the application Per WorkManager CountStatistic All High AlarmsFiredCount alarmManagerModule.numFired.name 3 The number of alarms fired Per WorkManager CountStatistic All High AlarmLatencyDuration alarmManagerModule.latency.name 4 The latency of alarms fired in milliseconds Per WorkManager RangeStatistic All High AlarmsPendingSize alarmManagerModule.alarmsPending.name 5 The number of alarms waiting to fire Per WorkManager RangeStatistic All High AlarmRate alarmManagerModule.alarmsPerSecond.name 6 The number of alarms firing per second Per WorkManager RangeStatistic All High