Trace output
Trace output allows administrators to examine processes in the appserver and diagnose various issues.
On an appserver, trace output can be directed either to a file or to an in-memory circular buffer. If trace output is directed to the in-memory circular buffer, it must be dumped to a file before it can be viewed.
On an application client or stand-alone process, trace output can be directed either to a file or to the process console window.
In all cases, trace output is generated as plain text in either basic, advanced or log analyzer format as specified by the user. The basic and advanced formats for trace output are similar to the basic and advanced formats that are available for the JVM message logs.
Basic and advanced format fields
Basic and Advanced Formats use many of the same fields and formatting techniques. The fields that can be used in these formats include:
- TimeStamp
- The timestamp is formatted using the locale of the process where it is formatted. It includes a fully qualified date (YYMMDD), 24 hour time with millisecond precision and the time zone.
- ThreadId
- An 8 character hexadecimal value generated from the hash code of the thread that issued the trace event.
- ThreadName
- The name of the Java™ thread that issued the message or trace event.
- ShortName
- The abbreviated name of the logging component that issued the trace event. This is typically the class name for WAS internal components, but may be some other identifier for user applications.
- LongName
- The full name of the logging component that issued the trace event. This is typically the fully qualified class name for WAS internal components, but may be some other identifier for user applications.
- EventType
- A one character field that indicates the type of the trace event. Trace types are in lower case. Possible values include:
- >
- a trace entry of type method entry.
- <
- a trace entry of type method exit.
- 1
- a trace entry of type fine or event.
- 2
- a trace entry of type finer.
- 3
- a trace entry of type finest, debug or dump.
- Z
- a placeholder to indicate that the trace type was not recognized.
- ClassName
- The class that issued the message or trace event.
- MethodName
- The method that issued the message or trace event.
- Organization
- The organization that owns the application that issued the message or trace event.
- Product
- WAS ND v7.0 that issued the message or trace event.
- Component
- The component within WAS that issued the message or trace event.
Basic format
Trace events displayed in basic format use the following format:
<timestamp><threadId><shortName><eventType>[className][methodName]<textmessage> [parameter 1] [parameter 2]
Advanced formats
Trace events displayed in advanced format use the following format:
<timestamp><threadId><eventType><UOW><source=longName>[className][methodName] <Organization><Product><Component>[thread=threadName] <textMessage>[parameter 1=parameterValue][parameter 2=parameterValue]
Log analyzer trace format
Preserves trace information in the same format as produced by Showlog tool.
Related tasks
Manage the appserver trace service