Home

 

Optional parameters

 

CommandScope (MQCFST)

Command scope (parameter identifier: MQCACF_COMMAND_SCOPE). This parameter applies to z/OS only.

Specifies how the command is executed when the queue manager is a member of a queue-sharing group. You can specify one of the following:

  • blank (or omit the parameter altogether). The command is executed on the queue manager on which it was entered.

  • a queue manager name. The command is executed on the queue manager you specify, providing it is active within the queue sharing group. If you specify a queue manager name other than the queue manager on which it was entered, be using a queue-sharing group environment, and the command server must be enabled.

The maximum length is MQ_Q_MGR_NAME_LENGTH.

InboundDisposition (MQCFIN)

Inbound transmission disposition (parameter identifier: MQIACH_INBOUND_DISP). This parameter applies to z/OS only.

Specifies the disposition of the inbound transmissions that are to be handled. The value can be:

MQINBD_Q_MGR

Listen for transmissions directed to the queue manager. This is the default.

MQINBD_GROUP

Listen for transmissions directed to the queue-sharing group. This is permitted only if there is a shared queue manager environment.

IPAddress (MQCFST)

IP address (parameter identifier: MQCACH_IP_ADDRESS). This parameter applies to z/OS only.

The IP address for TCP/IP specified in IPv4 dotted decimal, IPv6 hexadecimal, or alphanumeric form. This parameter is valid only for channels that have a TransportType of MQXPT_TCP.

The maximum length of the string is MQ_IP_ADDRESS_LENGTH.

ListenerName (MQCFST)

Listener name (parameter identifier: MQCACH_LISTENER_NAME). This parameter does not apply to z/OS.

The name of the listener definition to be started. On those platforms on which this parameter is valid, if this parameter is not specified, the default listener SYSTEM.DEFAULT.LISTENER is assumed. If this parameter is specified, no other parameters may be specified.

The maximum length of the string is MQ_LISTENER_NAME_LENGTH.

LUName (MQCFST)

LU name (parameter identifier: MQCACH_LU_NAME). This parameter applies to z/OS only.

The symbolic destination name for the logical unit (LU) as specified in the APPC side information data set. The LU must be the same LU that is specified in the channel initiator parameters to be used for outbound transmissions. This parameter is valid only for channels with a TransportType of MQXPT_LU62.

The maximum length of the string is MQ_LU_NAME_LENGTH.

Port (MQCFIN)

Port number for TCP (parameter identifier: MQIACH_PORT_NUMBER). This parameter applies to z/OS only.

The port number for TCP. This parameter is valid only for channels with a TransportType of MQXPT_TCP.

TransportType (MQCFIN)

Transmission protocol type (parameter identifier: MQIACH_XMIT_PROTOCOL_TYPE).

The value can be:

MQXPT_LU62

LU 6.2.

MQXPT_TCP

TCP.

MQXPT_NETBIOS

NetBIOS.

MQXPT_SPX

SPX.

On platforms other than z/OS, this parameter is invalid.

 

Parent topic:

Start Channel Listener