Home
Optional parameters
- CommandScope (MQCFST)
- Command scope (parameter identifier: MQCACF_COMMAND_SCOPE).
Specifies how the command is executed when the queue manager is a member of a queue-sharing group. We can specify one of the following:
- blank (or omit the parameter altogether). The command is executed on the queue manager on which it was entered.
- a queue manager name. The command is executed on the queue manager you specify, providing it is active within the queue sharing group. If you specify a queue manager name other than the queue manager on which it was entered, be using a queue-sharing group environment, and the command server must be enabled.
- an asterisk (*). The command is executed on the local queue manager and is also passed to every active queue manager in the queue-sharing group.
The maximum length is MQ_QSG_NAME_LENGTH.
- ObjectName (MQCFST)
- Name of object to be included in the processing of this command (parameter identifier: MQCACF_OBJECT_NAME).
Use this to specify the name of the object to be included in the processing of this command.
Generic names are supported. A generic name is a character string followed by an asterisk (*), for example ABC*, and it selects all objects having names that start with the selected character string. An asterisk on its own matches all possible names.
The maximum length is MQ_OBJECT_NAME_LENGTH.
- ObjectType (MQCFIN)
- Object type for which configuration data is to be refreshed (parameter identifier: MQIACF_OBJECT_TYPE).
Use this to specify the object type for which configuration data is to be refreshed. This parameter is valid only if the value of RefreshType is MQRT_CONFIGURATION. The default value, in that case, is MQOT_ALL. The value can be one of:
- MQOT_AUTH_INFO
- Authentication information object.
- MQOT_CF_STRUC
- CF structure.
- MQOT_CHANNEL
- Channel.
- MQOT_NAMELIST
- Namelist.
- MQOT_PROCESS
- Process definition.
- MQOT_Q
- Queue.
- MQOT_LOCAL_Q
- Local queue.
- MQOT_MODEL_Q
- Model queue.
- MQOT_ALIAS_Q
- Alias queue.
- MQOT_REMOTE_Q
- Remote queue.
- MQOT_Q_MGR
- Queue manager.
- MQOT_CFSTRUC
- CF structure.
- MQOT_STORAGE_CLASS
- Storage class.
- RefreshInterval (MQCFIN)
- Refresh interval (parameter identifier: MQIACF_REFRESH_INTERVAL).
Use this to specify a value, in minutes, defining a period immediately prior to the current time. This requests that only objects that have been created or altered within that period (as defined by their AlterationDate and AlterationTime attributes) are included.
Specify a value in the range zero through 999 999. A value of zero means there is no time limit (this is the default).
This parameter is valid only if the value of RefreshType is MQRT_CONFIGURATION.
Parent topic:
Refresh Queue Manager
pc13720_
Home