Home
Extended responses to commands using CommandScope
If a command uses the CommandScope parameter, or causes a command using the CommandScope parameter to be generated, there is an initial response set from the queue manager where the command was received. Then a separate set, or sets, of responses is generated for each queue manager to which the command is directed (as if multiple individual commands were issued). Finally, there is a response set from the receiving queue manager which includes an overall summary response (type MQCFT_XR_SUMMARY). The MQCACF_RESPONSE_Q_MGR_NAME parameter structure identifies the queue manager that generates each set.
The initial response set has the following additional parameter structures:
- MQIACF_COMMAND_INFO (MQCFIN). Possible values in this structure are MQCMDI_CMDSCOPE_ACCEPTED or MQCMDI_CMDSCOPE_GENERATED.
- MQIACF_CMDSCOPE_Q_MGR_COUNT (MQCFIN). This indicates the number of queue managers to which the command is sent.
Parent topic:
Extended responses
pc10500_