CICS adapter" />
Modifying a connection from the CICS adapter control panels
From the initial panel:
- Select Connection from the menu bar.
- Select the Modify action from the pull-down menu.
- Use the Modification Options secondary parameter window to specify the option you require.
To change the trace number:
- Enter 4 in the options selection field
- Enter a number, in the range zero through 199, in the trace number field. Do not change the 4 in the options selection field before you press Enter. If you do, the trace number is not changed.
- Press Enter to confirm your choice.
- Repeat steps 1 through 4, as required.
Figure 18. Modifying a connectionConnection CKTI Task +--------------------+-------------------------------------------------------- | Select an action. |CS Adapter Control -- Initial panel | | | 3 1. Start... |sing Tab key. Then press Enter. | 2. Stop... | | 3. Modify... | +--------------------------------+ | 4. Display | | Modification Options | | | | | +--------------------+ | Select modify option. Then | | F1=Help F12=Cancel | | press Enter. | +--------------------+ | | | 4 1. Reset statistics | | 2. Enable API Exit | | 3. Disable API Exit | | 4. Change Trace Number 123 | +--------------------------------+ IBM WebSphere MQ for z/O| F1=Help F12=Cancel | +--------------------------------+ F1=Help F3=Exit