example recovery scenarios, BSDS (bootstrap data set), bootstrap data set (BSDS), CSQJ102E message" />
Both copies of the BSDS are damaged
- Symptoms
- WebSphere MQ issues the following messages:
CSQJ107E +CSQ1 READ ERROR ON BSDS DSNAME=... ERROR STATUS=0874 CSQJ117E +CSQ1 REG8 INITIALIZATION ERROR READING BSDS DSNAME=... ERROR STATUS=0874 CSQJ119E +CSQ1 BOOTSTRAP ACCESS INITIALIZATION PROCESSING FAILED- System action
- Queue manager startup processing is terminated.
- System programmer action
- Carry out these steps:
- Rename the data set, and define a replacement for it.
- Locate the BSDS associated with the most recent archive log data set, and copy it to the replacement data set.
- Use the print log map utility to print the contents of the replacement BSDS.
- Use the print log records utility to print a summary report of the active log data sets missing from the replacement BSDS, and to establish the RBA range.
- Use the change log inventory utility to update the missing active log data set inventory in the replacement BSDS.
- If dual BSDS data sets had been in use, copy the updated BSDS to the second copy of the BSDS.
- Restart the queue manager.
- Operator action
- None.