IBM Tivoli Directory Integrator
Using the Update mode
The most common and simple pattern for using a Connector in Update
mode is:
- Using the Config
Editor, add a Connector in Update mode to our workspace. See Creating a Connector.
- Set the mode (Update) and other connection parameters for this
Connector in the Connection tab; required parameters
are marked with an asterisk (*). Some Connectors require you to configure
a Parser as well in the Parser tab.
- Set up the Attribute Map; see Input Attribute mapping.
- Open the Link Criteria tab on the Connector
configuration window and set up the rules for attribute matching.
Here we have a couple of choices:
- Click Add to add a new Link Criterion and
select an attribute from the connected system, the matching operator
(for example, Equals, Begins With, and so forth) and then the Work entry
attribute to be matched. When the Connector performs the
Lookup, it creates the underlying API or protocol syntax based on
the Link Criteria we have specified, keeping the solution independent
of the type of system used. We can add multiple Link Criteria, which
are connected by the Boolean operator AND, together to build the search
call.
- We can also select Build criteria with custom script, which opens a script editor window where we can create our own search
string, passing this back to the Connector using the ret.filter object.
For example:
ret.filter = "uid=" + work.getString("uid");
Note that Expressions can also be used to dynamically specify
the Attribute or Value to use for any Link Criteria. See Expressions for information. Also
see Link Criteria for more details
about Link Criteria.
Entries with the Attributes we have selected to map on input
are added in the data source during the AssemblyLine's execution.
To use the Connector in an AssemblyLine, drag it from its location
in <workspace>/Resources/Connectors to the Flow section
of an AssemblyLine. We can now map Work entry attributes to the output
by dragging attributes that were mapped in previously, onto the Update
Connector in the Attribute Maps window of the
AssemblyLine.
We can also create entirely new Attributes by right-clicking on
the Connector in this window, and selecting Add attribute
map item.
In Update mode, multiple entries can be updated. See "AssemblyLine
and Connector mode flowcharts" in IBM Tivoli Directory Integrator V7.1 Reference
Guide.
Parent topic: Update mode