+

Search Tips | Advanced Search

Lock manager codes (X'D3')

If a lock manager reason code occurs that is not listed here, an internal error has occurred. Collect the following diagnostic items and contact the IBM support center.


Diagnostics

  • A description of the actions that led to the error or, if applicable, either a listing of the application program or the input string to a utility program that was being run at the time of the error.
  • The console output for the period leading up to the error.
  • The queue manager job log.
  • The system dump resulting from the error.
  • If we are using CICS , the CICS transaction dump output.
  • Appropriate WebSphere MQ, z/OS, Db2, CICS, and IMS service levels.

    00D301F1

    An attempt to obtain storage was unsuccessful. This is probably because there is insufficient storage in your region.

    System action

    The current execution unit terminates with completion code X'5C6'.

    System programmer response

    Check that we are running in a region that is large enough. If not, reset the system and restart the queue manager. If this is not the cause of the problem, collect the items listed in Diagnostics and contact the IBM support center.

    00D301F2

    An attempt to obtain storage was unsuccessful. This is probably because there is insufficient storage in your region.

    System action

    The current execution unit terminates with completion code X'5C6'.

    System programmer response

    Check that we are running in a region that is large enough. If not, reset the system and restart the queue manager. If this is not the cause of the problem, collect the items listed in Diagnostics and contact the IBM support center.

    00D301F3

    An attempt to obtain storage was unsuccessful. This is probably because there is insufficient storage in your region.

    System action

    The current execution unit terminates with completion code X'5C6'.

    System programmer response

    Check that we are running in a region that is large enough. If not, reset the system and restart the queue manager. If this is not the cause of the problem, collect the items listed in Diagnostics and contact the IBM support center.

    00D301F4

    An attempt to obtain storage was unsuccessful. This is probably because there is insufficient storage in your region.

    System action

    The current execution unit terminates with completion code X'5C6'.

    System programmer response

    Check that we are running in a region that is large enough. If not, reset the system and restart the queue manager. If this is not the cause of the problem, collect the items listed in Diagnostics and contact the IBM support center.

    00D301F5

    An attempt to obtain storage was unsuccessful. This is probably because there is insufficient storage in your region.

    System action

    The current execution unit terminates with completion code X'5C6'.

    System programmer response

    Check that we are running in a region that is large enough. If not, reset the system and restart the queue manager. If this is not the cause of the problem, collect the items listed in Diagnostics and contact the IBM support center.

    00D302F1, 00D302F2, 00D302F3, 00D302F4, 00D302F5, 00D303F1, 00D303F2, 00D303F3, 00D304F1, 00D305F1, 00D306F1

    An internal error has occurred.

    System action

    The current execution unit terminates with completion code X'5C6'.

    System programmer response

    Collect the items listed in Diagnostics and contact the IBM support center.

    00D31094, 00D31095, 00D31096, 00D31097

    An internal error has occurred.

    System action

    The current execution unit terminates with completion code X'5C6'. In some cases, the queue manager might terminate with completion code X'6C6'.

    System programmer response

    Collect the items listed in Diagnostics and contact the IBM support center.

Parent topic: IBM MQ for z/OS codes

Last updated: 2020-10-04