2139 (085B) (RC2139): MQRC_CNO_ERROR
Explanation
On an MQCONNX call, the connect-options structure MQCNO is not valid, for one of the following reasons:- The StrucId field is not MQCNO_STRUC_ID.
- The Version field specifies a value that is not valid or not supported.
- The parameter pointer is not valid. (It is not always possible to detect parameter pointers that are not valid; if not detected, unpredictable results occur.)
- The queue manager cannot copy the changed structure to application storage, even though the call is successful. This can occur, for example, if the parameter pointer points to read-only storage.
Completion code
MQCC_FAILED
Programmer response
Ensure that input fields in the MQCNO structure are set correctly.