IBM Tivoli Composite Application Manager for Application Diagnostics, Version 7.1.0.1

Error CYNVE0181E: One or more data collectors were unable to be configured

The problem: When trying to configure 250 or a large number of data collects on the Unconfigured data collector Overview page in a single operation, you may get the error message "CYNVE0181E: One or more data collectors were unable to be configured". This can occur in a managing server with DB2 or Oracle as the database server.

The reason: Database connections run out during the configuration time and the default setting of maximum number of connections in DB2 or Oracle is not sufficient enough to handle all the database activities involved.

The solution: 50 or fewer number of data collectors is recommended when trying to configure them in a single operation.


Parent topic:

Run the Managing Server

+

Search Tips   |   Advanced Search