IBM Tivoli Composite Application Manager for Application Diagnostics, Version 7.1.0.1
Configure a data collector for multiple network cards and NATs - J2EE Agent
If a data collector needs to expose a specific IP to the Managing Server, complete one of the following steps:
- If the data collector is not using Port Consolidator:
- Specify a system property java.rmi.server.hostname for the application server and set it to the IP address of the data collector.
- Make sure that Managing server can access the IP address of the data collector (You can verify this by doing a ping).
- If the data collector is using Port Consolidator:
- Specify a system property java.rmi.server.hostname for the application server and set it to the IP address of the data collector.
- Specify a system property java.rmi.server.hostname in the start section of the script used to start Port Consolidator and set its value to the IP address of the data collector.
- Make sure that the Managing server can access the IP address of the data collector (You can verify this by doing a ping).
Parent topic:
Customization and advanced configuration for the data collector